Slow Earthquakes in the Pacific Northwest

Installation of Shelton Tiltmeter

We completed installation of the first biaixal tiltmeter near Olympia at the Shelton airport. Since it is difficult to excavate trenches deeper than 2.5 m, the long baseline tiltmeter must follow topogrpahic contours. Ideally, the ends of the tiltmeter will be in a region that is well drained although we are constructing sensor systems that can operate submerged for extended periods to mitigate for large annual rainfall in the Pacific Northwest.

Tiltmeter Installation
Pipe in Open Trench
Tiltmeter Installation
Driving Pier Monument
Tiltmeter Installation
Setting Cover Lid

The tiltmeter consists of two arms approximaely at right angles, in an L-shape plan view. The sensors are placed ~2 m underground and operate in three vaults accessed via 2' diameter concrete manhole lids. Cellular frequency transmission of data signal from each vault are transmitted to an AC data-logging computer stored inside. Data are then uploaded to CWU once daily.

Data stored in the computer are accessed via cell-phone through the internet. Power to the tiltmeter comes through an AC hookup (120V at 0.2 Amp is equivalent to a 25W light bulb).



Map View of Pipe Location

Data are transmitted to a nearby computer via radio links every few seconds; the computer forwards data to analysis centers in Ellensburg, Washington and Boulder, Colorado. Three of these tiltmeters have now been installed in the Puget Sound region monitoring earthquake activity tens of miles underground. Data from the tiltmeters will help understand how increments in stress eventually lead to large earthquakes.

Data

Calibration
E-W Arm Calibration Test.
Sumatra EQ
Elevation Data During the Sumatra EQ